OMS (OPERATING MONITORING SYSTEM)
The system of supervision and operation of the boiler for solid fuels. To make the boiler operation even more convenient and comfortable, the device has been equipped with a system that controls the amount of fuel in the tank, as well as the amount of ash in the ash pit. So far, boilers on the market have not been equipped with such systems and it was the responsibility of the user to remember about backfilling the tank and selecting ash. The system constructed by KOSTRZEWA measures and informs the user well in advance about the planned activities (i.e. about backfilling and cleaning the ash pan). The information is displayed in the form of a prompt on the screen of the boiler controller and the room regulator. The solution is reserved in the Patent Office of the Republic of Poland..
OMS (OPERATING MONITORING SYSTEM)
The system of supervision and operation of the boiler for solid fuels. To make the boiler operation even more convenient and comfortable, the device has been equipped with a system that controls the amount of fuel in the tank, as well as the amount of ash in the ash pit. So far, boilers on the market have not been equipped with such systems and it was the responsibility of the user to remember about backfilling the tank and selecting ash. The system constructed by KOSTRZEWA measures and informs the user well in advance about the planned activities (i.e. about backfilling and cleaning the ash pan). The information is displayed in the form of a prompt on the screen of the boiler controller and the room regulator. The solution is reserved in the Patent Office of the Republic of Poland.
BOILER EEI PELLETS 8 - 32 KW WITH PLATINUM BIO VG
We invite you to watch the animation presenting the operation of the KOSTRZEWA EEI Pellets 8-32 kW boiler.
Our boilers are tested in an accredited research unit associated in the international organization "Association of Accreditation".
The test results confirm that the KOSTRZEWA brand products meet the emission requirements set out in the Ecodesign Directive, as well as ensure the safety of use.
Each tested type of boiler passes over 20 different tests, including
Testing of boiler's resistance to 4 bar pressure
Test of efficiency and emissions at 10%, 11% and 13% oxygen
Research on the actual consumption of electricity in each mode of operation and standby
Test for work in a closed system without additional safeguards
Thanks to this, our boilers appear on state subsidy lists of equipment from many EU countries.
AUTOMATICS PLATINUM BIO ECOMAX 860P TOUCH WITH COLOR TOUCH PANEL OPERATORS
Device made in advanced technology that controls the combustion process in the boiler and pellet burner.
Automation controls: fuel feed from the tank, feeder, pressure fan, igniter, heating pump, hot water pump, fuel level sensor, boiler pump / buffer, circulation pump (optional), linear actuator, buffer (optional) and additional three mixing valves, a mixer of the heating circuit and additional two mixing valves - module C (optional).
Optional equipment: external temperature sensor, central heating sensor, hot water sensor, return temperature sensor, ecoSTER TOUCH color room panel with remote boiler control, room thermostat, weekly wireless programmable, weekly wired programmable room thermostat, temperature sensor with regulation, EcoLAMBDA lambda sensor set, additional extension module (C), EcoNET internet module.
POWER OF THE BOILER | A HEATING AREA | |
---|---|---|
m2 | m3 | |
8 kW | 30-140 | 75-350 |
10 kW | 30-160 | 75-400 |
16 kW | 85-200 | 212-500 |
24 kW | 100-300 | 250-750 |
32 kW | 150-400 | 375-1000 |
The surface is given at a room height of 2.5 m.
Specification
8 kW | 10 kW | 16 kW | 24 kW | 32 kW | ||
---|---|---|---|---|---|---|
Ciąg kominowy | mbar | 0,15-0,20 | 0,15-0,20 | 0,15-0,20 | 0,15-0,20 | 0,15-0,20 |
Pojemność wodna | l | 44 | 44 | 58 | 65 | 102 |
Maksymalne ciśnienie robocze | bar | 2 | 2 | 2 | 2 | 2 |
Ciśnienie testu | bar | 4 | 4 | 4 | 4 | 4 |
Temperatura spalin dla mocy nominalnej | °C | 89,2 | 100 | 112,9 | 140,9 | 129,2 |
Temperatura spalin dla mocy minimalnej | °C | 68,3 | 68,3 | 72,7 | 78,3 | 79,2 |
Strumień masy spalin dla mocy minimalnej | kg/s | 0,00542 | 0,00644 | 0,00889 | 0,01419 | 0,02108 |
Strumień masy dla mocy minimalnej | kg/s | 0,00301 | 0,00301 | 0,00283 | 0,00442 | 0,00556 |
Średnica czopucha | mm | 127 | 127 | 159 | 159 | 159 |
Opory przepływu dla 10 K | mbar | 5,23 | 5,45 | 1,7 | 3,8 | 4,2 |
Opory przepływu dla 20 K | mbar | 4,84 | 4,9 | 0,5 | 1,1 | 1,5 |
Nominalna moc cieplna | kW | 8,3 | 10 | 15 | 24 | 32 |
Zakres mocy cieplnej | kW | 2,5-8,3 | 2,5-10 | 4,4-15 | 7,2-24 | 8,7-32 |
Sprawność dla mocy nominalnej | % | 92,2 | 91,6 | 92,2 | 91,3 | 90,6 |
Sprawność dla mocy minimalnej | % | 87,5 | 87,5 | 90,3 | 91,7 | 90,4 |
Klasa kotła wg EN 303-5:2012 | 5 | 5 | 5 | 5 | 5 | |
Okres spalania dla mocy nominalnej (wartość opałowa paliwa: 17 280 kJ/kg) |
h | 93 | 79 | 52 | 48 | 32 |
Zakres ustawień regulatora temperatury | °C | 50-80 | 50-80 | 50-80 | 50-80 | 50-80 |
Minimalna temperatura wody na powrocie | °C | 45 | 45 | 45 | 45 | 45 |
Rodzaj paliwa | Klasa | Granulat z trocin (pellets wykonany zgodnie z EN 303-5:2012 / PN- EN ISO 17225-2 klasa C1 / A1) Paliwo testowe użyte w procesie certyfikacji - A1. Może również spalać pelet A2 i B. |
||||
Pojemność zbiornika paliwa | l | 290 | 290 | 290 | 290 | 290 |
Wymiary otworu zasypowego | mm | 340x211 | 340x211 | 340x211 | 440x211 | 440x211 |
Zasilanie | V / Hz / A | 230 / 50 / 2 | 230 / 50 / 2 | 230 / 50 / 2 | 230 / 50 / 2 | 230 / 50 / 2 |
Pobór mocy elektrycznej dla mocy nominalnej | W | 56 | 56 | 82 | 128 | 74 |
Pobór mocy elektrycznej dla mocy minimalnej | W | 20 | 20 | 23 | 27 | 39 |
Pobór mocy elektrycznej w trybie STANDBY | W | 2 | 2 | 2 | 2 | 2 |
Maksymalny pobór mocy elektrycznej | W | 485 | 485 | 492 | 492 | 509 |
Maksymalne natężenie dźwięku | dB | 52 | 52 | 52 | 52 | 52 |
Średnica paliwa | mm | 6 | 6 | 6 | 6 | 6 |
Ceramics is everywhere for even smaller combustion, lower emissivity and even higher efficiency of the boiler exchanger chamber and burner with the highest quality ceramic. During operation, ceramics are heated to temperatures above 1000 ° C, resulting in an extremely efficient combustion of biomass.
The exhaust turbulators used also cause a greater retention of energy in the boiler.
Our technical consultant is at your disposal at no. telephone +48 663 76 79 75